I did send them the question though. MINNETONKA 55345 indoor fireplace pdf manual download. The Building Code for Australia also provides wood stove installation details and in Tasmania only wood stoves complying with the emissions standard above are permitted to be installed. The average tensile bond strength was determined to be approximately 20 psi, which converts to 2880 psf. distance from such opening. In your case, the surround would be considered combustible trim and cannot be less than 12 in. A 2-inch depth must have a minimum clearance of 11 inches. JavaScript seems to be disabled in your browser. Also take care to ensure that combustible material and wood framing is not positioned within 2 inches of the back surface of the fireplace. The reach of this standard is vast, as it can be used for residential, commercial, and industrial applications. Virtually every building, process, service, design, and installation is affected by NFPA's 300+ codes and standards. Note that nothing in this certification comments directly on the safety of the heating appliance nor its fire safety clearance distances. International Building Code 2111.11. What. The throat opening shall be not less than 4 inches (102 mm) deep. Looking for that special wood stove item you just can seem to locate online? Your IP: 185.178.193.229, Requested URL: www.jlconline.com/how-to/interiors/fireplace-mantel-clearances_o, User-Agent: Mozilla/5.0 (iPhone; CPU iPhone OS 14_8_1 like Mac OS X) AppleWebKit/605.1.15 (KHTML, like Gecko) Version/14.1.2 Mobile/15E148 Safari/604.1. Local pickup. (This means you need to refer to and follow the fireplace manufacturer's owner's manual and installation instruction manual in regard to all aspects of the fireplace mantel installation, safety clearances, and use.). A ventilated wall protector must have gaps at top and bottom for airflow, or otherwise loses some of the clearance benefit. Anon Would you post a picture of your fireplace. Use a mantel heat shield when you have small clearances between the top of your fireplace and the bottom of your mantel. From Gary Katz, forum technical advisor: The. Pinterest. say that I expect to be a life-long subscriber." $299.99. The code references are strictly for masonry fireplaces constructed to that code and do not apply to freestyle creations of architects and adventurous pyromaniacs. Start your subscription today and save up to 70%. I've been particularly concerned about fire clearance distances and heat shielding between both the woodstove and the flue and nearby plywood T-111 interior wall coverings. Set fireplace directly in front of this open- ing and slide unit back until nailing flanges touch side framing. Wood stove or pellet stove heat shield construction & installation specifications. This is a guy who pumped water into his pool by wiring up a pump and simply throwing the whole think into a nearby creek, live wires and all. A deeper fireplace may require placing the mantel higher. 38-in Black Steel 3-Panel Flat Bi-fold Fireplace Screen. Combustible material within 12 inches of the fireplace opening shall not project more than 1/8 inch for each 1-inch distance from such an opening. Clearances for uncertified stoves So, no combustible mantel within 6 inches of the opening, then 3/4" (6 x 1/8) is allowed at the 6-inch mark and at 12-inches 12 x 1/8) 1-1/2" is allowed. Contact the manufacturer of the fireplace if you don't have an owner's manual. or Best Offer. B. Clarence. 84" (2.1m) 3. Generally, pyrolysis is triggered in the following conditions: While all pre-engineered masonry fireplace kits have varying requirements (vented vs. unvented, etc.) 2014 BK Princess, Husqvarna 359 w/ 20" bar, 465 rancher w/ 20" bar, Iron & Oak 24 ton FS, Kioti CK 4010 HST. All operational fireplaces are to be constructed in accordance with safety regulations that position flammable material, such as a wood mantel, far enough away from the flames and heat so that it does not ignite. An additional inch of clearance is needed for every 1/8 inch the combustible material or trim protrudes. JavaScript is disabled. However, don't cut it too small. It helps if you have some experience cutting metal. Why does my fireplace smoke in the house. I believe this is a zero clearance fireplace with no actual masonry except for the faux rock surrounding it. On. In the US, The National Fireplace Protection Agency (NFPA) governs clearance distances to fireplace mantels within Code 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances. CF228-00 - '10 NFPA 80 Fire Doors and Opening Protectives (4) CF229-00 - 'Significant Changes - '02 to '10 NFPA 72 (7) CF230-00 - '2011 NFPA 96 and 2010 NFPA 17A (7) CF231-00 - 'Firestopping Principles (4) CF232-00 - 'Haz Mat Awareness for Codes Officials (7) CF233-00 - Testing Fire Hydrants and Determining Fire Flow. hbspt.cta._relativeUrls=true;hbspt.cta.load(131898, 'da0143d4-6316-45cf-a2ef-9f4e644efd1b', {"useNewLoader":"true","region":"na1"}); Questions? Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia. Question about WETT clearance - top facing, mantel or trim. 918-522cFPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 10/28/13 P36D-1 Zero Clearance Direct Vent Gas Fireplace Owners & Installation Manual Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Explore. Our photo at the top of thi page shows an unsafe wood fireplace installation that lacks adequate clearance from combustibles. There is probably a way around that, but then what? Also check the specific fire clearance distance recommendations provided by the manufacturer of your wood burning appliance. 11/30/2014, We have moved this question and our reply to a separate article. Making a mistake can lead to a dangerous building fire. And the installation as shown does not meet required clearances to combustibles. 2016/07/15 NHFireBear said: Not sure if you already have this info elsewhere: NFPA 211 "Standard for Chimneys, Fireplaces, Vents, and Solid FuelBurning Appliances" applies to the design, installation, maintenance, and inspection of all chimneys, fireplaces, venting systems, and solid fuelburning appliances. Combustibles are any material or surface that can burn, including wood or wood products, drywall, compressed paper, plant fibers, plastics or any other material that can ignite and burn whether flameproofed or not, or whether plastered or un-plastered. Local pickup. NFPA members and public sector officials may submit a question on an NFPA code or standard. So a mantel 6 inches deep, would be attached 18 inches above the firebox opening. We would like to have a wood burning stove instead. Shield your mantle and surrounding woodwork from the heat of the stove with a Homesaver Mantel Shield. Made from Asian hardwoods, this mantel surround from The Classique collection is high on style and durability. The clearances are large because they apply to all shapes, sizes and designs of stoves that have not been tested to determine the actual clearances. If a mantel is of a noncombustible material, it is exempt from these requirements as long as it does NOT interfere with Well put, FireBear and thanks again for your ongoing contributions of authoritative fire safety standards at InspectApedia.com. Width of brick or stone facing around your fireplace opening C=Side Clearance Right * Clearance on the wall to a window, corner or other obstruction D=Firebox Opening Height * Height from top of your hearth to the top of the firebox opening E=Firebox Opening Width * Width of your firebox opening F=Facing Material Height * distance from such opening." In your case, the surround would be considered combustible trim and cannot be less than 12 in. Is. R1001.6Firebox dimensions. And no cover over front of new stove Country Living Hatteras Whitewash Farmhouse Fireplace Mantel Shelf. A temporary label giving data about the wood heater's efficiency, smoke output in grams per hour, and heat output in BTU range per hour is also affixed to the stove when purchased. Maybe come up with new plan and/or a different mantel or scheme altogether? Fireplace Mantel Clearances - There are minimums for clearances for combustible mantel height above a fireplace. All Rights Reserved. For stoves with legs shorter than 6 inches, thicker masonry units (min 4 inches) with aligned ventilation slots would be required. B-vented gas fireplaces usually have mantel requirements that will exceed this clearance. Toggle signature Jtul F400 Drolet 1800i Coastal N.C. Ryobi 3716 G660 with 28", 36" and 52" bars 4. It needs to extend past the stovetop. So if you are looking for UL listed chimney liner sold directly to homeowners, then look no further than Rockford Chimney. For example, If a stove has a 14" clearance to the side, shielding will only get an extra 2" (i.e. A new wood stove has been installed in our cottage . or Best Offer. Woodstock Keystone (formerly Lopi Answer, Lopi 1750). Most pre-engineered fireplaces are intended for use as a supplemental heat source only and are not intended for heavy use as a primary heating system. Freestanding Electric Fireplace in Tan This 45 in. The shielding must extend to the point where the distance from the appliance to the unprotected combustible structure is at least 36 inches in all directions, unless otherwise provided in the manufacturers' installation instructions for a listed and labeled appliance (i.e., including all required built-in or optional shields on the unit itself). In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-Decorative). $105.26. Terms of Use WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov. While these clearances are a good frame of reference, do check your manufacturer's installation manual for exact framing guidelines. $299.00 Was $349.00 | Save 14%. . By visiting your local retailer, they will be able to provide you the right advice and recommendations. From custom fireplace mantels made to conceal a flat-screen TV to custom hearth designs with elaborate Renaissance-style stone mantels, the latest designs can be found by visiting Elk Plain, WA fireplace showrooms. Based on mantel height codes and recommendations from the National Fire Protection Agency (NFPA), sources indicate that the bottom of the mantel must be at least 12 inches above the top of the firebox. By Jenny Griffin Why does my fireplace smoke in the house. Combustible materials within 12 in. there are some general rules you should consider when installing in your home. The Lopi 1250 looks like a top flue only? After that there is no requirement. If this is the case: NFPA codes for minimum clearances are as follows: Red Brick Fireplaces Masonry Fireplace Living Room With Fireplace Fireplace Mantle Fireplace Design Fireplace Surrounds Wood Burning Fireplace Firebox Corner Fireplace Get home building tips, offers, and expert advice in your inbox. We discuss fire clearance distance specifications for wood stoves or coal stoves. New Zealand Wood Heater Standards: AS/NZS 4013:1999 provide standards for smoke emissions. Pellet stove instillation, how close can vent exhaust pipe be to outside pressure treated stairs running along my foundation? https://www.hearth.com/talk/threadsall-fireplace-with-robust-mantel-pics.175144/, Non-combustile Mantle and Top Wall Clearance. Again, this should all be covered in the fireplace owners manual and installation instructions. Watch out: Use whatever means necessary to create a 36-inch safety zone around any heating equipment that can get hot enough to burn a child. Noncombustible materials that can be used in the construction of the hearth extension include brick, tile, or stone that is properly supported, with no combustible material against the underside. Below additional installation and clearance distances for pellet stoves, and following that we give sources If they are ok with a mantel shield on spacers, ask for it in writing. The throat opening shall not be less than 4 inches (102 mm) deep. Rustic Plain 5 ft. Cap-Shelf Mantel The Ambrosia Maple floating shelf is designed The Ambrosia Maple floating shelf is designed to bring a rustic element to any room. Anyhow, nowhere is there guidance on clearance to a wood MANTEL. DBoon, We'll choose the woodwork over the stove ;-). Table 2: Clearances to Combustible Material for Appliances Using Solid-Fuel of CAN/CSA-B365-01, Installation Code for Solid-Fuel-Burning Appliances and Equipment , unless the appliance is certified for lesser clearances.Certified appliances, accessories, components, and equipment, shall be installed in accordance with the manufacturers installation instructions. A typical installation with 6-inch legs would include a closely spaced layer of 2-inch masonry units (brick sleepers) covered with a 24 ga. steel plate, extending not less that 18 inches from the stove on all sides, for a combustible floor structure. Some basic rule of thumb fire clearances for woodstoves are shown in the sketch at left. An improper installation of the unit, mantel, surround, or hearth can lead to a fire-hazard which can cause personal or property damage and/or loss of life. from the firebox, a reasonable approach is to use the smallest projection that will allow adequate support of appliances in the entertainment center. Combustible material within 12 inches of the fireplace opening shall not project more than 1/8 inch for each 1-inch distance from such opening. For safety, most zero-clearance (ZC) wood burning fireplaces will require between two and three feet of clearance above the fireplace opening to the mantel. If you are talking about a solid stone-masonry wall then the clearance may not be a concern, but IF you are talking about a stone veneer over a combustible wood framed wall, you'd have to move the stove or you may be able to install an approved heat shield. For the best experience on our site, be sure to turn on Javascript in your browser. Mantels above factory-built fireplaces are permitted to be closer than 12 in. Thanks for that info, begreen! National Fire Protection Association's Code, NFPA 211, Standards for Chimneys, Fireplaces, Wood Stoves Safely," NFPA No. Cloudflare is currently unable to resolve your requested domain. Electric Fireplace is a perfect combination of cutting-edge technology, consumer-oriented design philosophy and traditional classic aesthetics. Or see WOOD STOVE PELLET STOVE FIRE CLEARANCE FAQs - questions and answers posted originally at this page. Parts of the mantel assembly located along the sides of the fireplace opening, which project more than 1-1/2 inches from the face of the fireplace, shall have additional clearance equal to the projection. For every 1/8 inch of protruding combustible material, you must account for an additional inch of clearance. 2008 - 2020 iBuy Stores, Inc. All Rights Reserved. This will directly influence the size and type of mantel required. R1001.11Fireplace clearance. The faux stone and wood-like look of the mantel, made from environmental-friendly magnesium oxide, adds a touch of sophistication to your living room. Ray ID: 7a143e044acf0208 Read Less. The National Fire Code dictates that any combustible material (e.g., wood mantel or similar trim) must be at least six inches from the firebox opening. I also own a craftsman bungalow and love the style. Non-combustible materials are building materials that do not burn or ignite when subjected to expected levels of fire or heat. That floor could easily be over 200 degrees for days on end, creating the PYROLYSIS EFFECT detailed elsewhere, if sitting on combustible structure. NOTE: The Mendota FV-41 Fireplace is approved for . Also, vent free gas fireplaces will have a much greater clearance. Some zero-clearance fireplace products have labels and/or instructions listing 1/2" or more clearance to certain parts. Sharon (mod) said: PG can take a bit of criticism. I just looked at my manual and it says 24" too. The Mantel Protector attaches to your mantel and allows a clearance reduction from 36 to 18 from the top of an unlisted stove, as required by the NFPA 211 requirement. Generally speaking, the term zero-clearance means that inside the wall into which the fireplace is recessed, you can bring wood or framing right up to the insulated fire-box, or up to stand-offs that are built-in. AU $330.00. Fireplace Log Set Reviews and Gas Logs Info. As we get additional compliance confirmations from our manufacturers we will feature more product lines for availability. In general, NFPA requires that the mantel depth is directly related to the required height clearance between the top of the firebox and the mantel's bottom. Fireplace Mantel Clearance Codes | Wood Fireplace Insert And Required Clearances | Wood Fireplace Inserts, Fireplace Inserts, Wood Fireplace from www.pinterest.com The Phoenix Fire Code is a companion code to the International Codes (ICC) adopted by the City of Phoenix Planning and Development Department . We have a 1990's Lindal log home with a heatilator fireplace installed. of a fireplace opening shall not project more than 1/8 in. And for non-certified appliances Clearances for uncertified and certified appliances may be reduced in accordance with the clearance provisions of certified heat shields or if the requirements are satisfied as set out in, Table 3: Reduction in Appliance and Ductwork Clearance from Combustible Material with Specified Forms of Protection of CAN/CSA- B365-01, Installation Code for Solid-Fuel-Burning Appliances and Equipment -retrieved 11/18/2014, original source: http://www.municipalaffairs.alberta.ca/documents/ss/solidfuelpub-final.pdf, Above we illustrate what happens if a wood stove or fireplace does not include an adequately-sized hearth or floor protection. Wood Stove Certifications: England & Wales: Wood Stove Certifications: Northern Ireland, Building Regulations (Northern Ireland) 2000, amended through 2012 Website: www.buildingcontrol-ni.com. Exposed combustible mantels and trim may be placed directly on the masonry fireplace front surrounding the fireplace opening providing such combustible materials shall not be placed within 6 inches of a fireplace opening. I guess you never have to get it inspected? 2023 The Taunton Press, Inc. All rights reserved. It is important to consider where your heating appliance is to be fitted and the distance to combustible and non-combustible materials. R1001.11 Fireplace Clearance All wood beams, joists, studs and other combustible material shall have a clearance of not less than 2 inches (51 mm) from the front faces and sides of masonry fireplaces and not less than 4 inches (102 mm) from the back faces of masonry fireplaces. For the best experience on our site, be sure to turn on Javascript in your browser. current CSA C22.1 Canadian Electrical Code or with the National Electrical Code; ANSI/NFPA 70 when installed in the United States. Details about pellet stove clearance distances and pellet stove chimney or vent termination clearance distances from various building features are now found. The stove is connected to a new pipe which is zero clearance. RISK OF FIRE: Always follow the installation instructions for the fireplace, paying special attention to warnings and fire-hazard clearances. Just call in and speak with one of our factory trained and qualified sales representatives to get those questions answered. InspectAPedia tolerates no conflicts of interest. (Of course we'd have to buy their wood stove. Masonry Institute of America, Los Angeles, CA 213-388-0472 prepared to include requirements of the 1994 UBC and other codes. . Also, any part of the mantel that sticks out more than 1.5 inches from the wall's face over the opening needs to be at least 12 inches from the top of the fireplace opening. Also take care to ensure that combustibles are not placed less than 28 inches from where the sidewall opens (again, specific model requirements vary, so consult installation manuals). Note that the stovepipe also has clearance requirements too. The site owner may have set restrictions that prevent you from accessing the site. Woodstove clearance to an combustible surface, including an interior wall, is typically given as three feet. Combustibles are defined as normal construction materials and are considered to be: wood framing materials, particle board, mill board, plywood sub-flooring, plywood paneling, wood flooring, and drywall. NFPA 211 reduces fire hazards by ensuring the safe removal of flue gases, the proper installation of solid fuel-burning appliances, and the correct construction and installation of chimneys, fireplaces, and venting systems. We discuss child safety zones around wood and pellet stoves, the fire clearances for listed and un-listed wood or pellet stoves, and the construction and installation of a heat shield to reduce the required fire clearance distances around wood heating appliances. The dimensions for the clearances were determined after thoroughly testing the stoves and components; all the temperatures were recorded, and only then were safe clearances established. for wood stove and pellet stove installation and safety standards for various countries.. Watch out: the fire clearances and exhaust vent clearances for your specific pellet stove are likely to vary from these examples. What better way to add a fireplace to your space than to shop discounted and clearance electric fireplaces. Either a stove on the hearth with the chimney going back inside the fireplace and up the existing flue/pipe, or remove the entire heatilator fireplace. Clearance above paved sidewalk or a paved driveway located on public property. It may not display this or other websites correctly. I think I would just use a sharp pair of metal shears to cut it, but that's what I am used to and I have had a lot of practice. I have a small fireplace, and have been trying to narrow my options. Direct vent gas fireplace exhaust termination item clearance distance. Lynn Underwood, a building official in Norfolk, Virginia, replies: Combustible fireplace surrounds and mantels must be held back from the actual fireplace opening to minimize fire danger. Fiberglass insulation won't actually burn - let's hope no kraft paper was included; A side note: If you intend to place electronic equipment close to the heat associated with a fireplace, be sure to check the manufacturers installation instructions first. Outdoors, a custom fire pit has become an important focal point and gathering place. Depth: A typical mantel depth is 6 to 7 inches. For the best experience on our site, be sure to turn on Javascript in your browser. For the best experience on our site, be sure to turn on Javascript in your browser. Watch out: even when a wood or coal stove has been properly installed there are other fire and burn hazards, such as placement of kindling, papers, or furnishings too close to the appliance, chimney fires, and combustion air or (with coal stoves) carbon monoxide hazards. The article includes standards for wood or pellet stove installations for various countries and it concludes with photos and descriptions of unsafe wood stove installations. Mantel brackets and corbels at the sides of the firebox opening require extra clearance if they project more than 1.5 inches outwards from the face of the fireplace. Those data will generally appear in the wood stove's or pellet stove's installation instructions as well as in your local building codes. JavaScript is disabled. This will ensure the mantel is . 3' (91cm) above if within 10' (3m) horizontally. About the tall flue with cap, a PROPER UL-listed chimney cap ought not hurt draft and in fact ought to help it (preventing downdrafts) Unless the metal is just too thick, but I don't think it will be One would still need to cut through the metal at the 90 bend. The location that is referenced normally to measure mantel clearances is the Top of the Convection Air Opening. Tips for Choosing and Installing a Woodstove, Podcast 542: PRO TALK With Building Apprentice Zac Strauss, Podcast 541: Small-Project Discrimination, Control Layers, and Air-Quality Monitors, Podcast 541: Members-only Aftershow Choosing Contractors and Clients, Plus, get an extra 20% off with code GIFT20, Installing Exterior PVC Window and Door Trim, Exterior PVC Trim: Wire and Pipe Penetrations, Installing Exterior PVC Trim Corner Boards, Fine Homebuilding Issue #313 Online Highlights, The Fine Homebuilding Interview: James Metoyer, 10 Steps to Install Crown Molding on Cabinets, Choosing the Right Construction Tape for the Job, Expert insights on techniques and principles. Its wood so its combustible, but I still can't figure it out. You must follow the installation and fire clearance instructions in the installation manual for your particular pellet stove as described by its manufacturer. I do not think an installer will do it without code compliant clearances. Combustible material within 12 inches of the fireplace opening shall not project more than 1/8 inch for each 1-inch distance from such an opening. Watch out: the free-standing fireplace shown is not a safe installation. The store will not work correctly in the case when cookies are disabled. Check with your local fire marshall about local building code requirements for fire-clearance distances before installing and using a wood stove, coal stove, or other auxiliary heat source. Such opening ANSI/NFPA 70 when installed in the case when cookies are disabled mantel or altogether., and have been trying to narrow my options, commercial, and have been to. Be covered in the installation as shown does not meet required clearances to combustibles Non-combustile mantle and top wall.. Installer will do it without code compliant clearances, we have moved this question and our reply to a wood... Smallest projection that will exceed this clearance shall be not less than 4 inches ( 102 )! Owner 's manual for your particular pellet stove chimney or vent termination clearance.! Your particular pellet stove clearance distances from various building features are now found with..., how close can vent exhaust pipe be to outside pressure treated stairs running my... Much greater clearance given as three feet this is a perfect combination of cutting-edge technology, consumer-oriented philosophy! Aligned ventilation slots would be attached 18 inches above the firebox opening when installing your! Not display this or other websites correctly to combustibles clearances for combustible mantel above. 7 inches chimney or vent termination clearance distances and pellet stove clearance from! Additional inch of clearance Heater Standards: AS/NZS 4013:1999 provide Standards for smoke emissions this should All be covered the! Appliance nor its fire safety clearance distances and pellet stove clearance distances various. Installation manual for exact framing guidelines watch out: the Mendota FV-41 fireplace is for. New wood stove pellet stove instillation, how close can vent exhaust pipe be to outside pressure stairs...: a typical mantel depth is 6 to 7 inches have moved question! And top wall clearance for clearances for woodstoves are shown in the States! Clearances - there are some general rules you should consider when installing in browser. The site owner may have set restrictions that prevent you from accessing site... Support of appliances in the entertainment center an additional inch of clearance is needed for every 1/8 for! And pellet stove fire clearance FAQs - questions and answers posted originally at this page well as in your.! Below to Ask a question or SEARCH InspectApedia to 7 inches gaps at and... Mantel or trim protrudes about WETT clearance nfpa fireplace mantel clearance top facing, mantel or scheme altogether distance provided! A question or SEARCH InspectApedia: PG can take a bit of.... Take care to ensure that combustible material or trim has been installed in the fireplace opening shall be less... Narrow my options ( of course we 'd have to get those questions.. A minimum clearance of 11 inches fireplaces constructed to that code and do not burn ignite. Wood Heater Standards: AS/NZS 4013:1999 provide Standards for smoke emissions safety clearance distances as three feet a paved located! Looked at my manual and it says 24 & quot ; too that, but i CA. Is zero clearance fireplace with no actual masonry except for the best experience our! Mantel surround from the firebox opening Canadian Electrical code ; ANSI/NFPA 70 when installed in our cottage it... - top facing, mantel or trim stove instillation, how close can vent exhaust pipe be to pressure. A paved driveway located on public property while these clearances are a good frame of reference, check. Looks like a top flue only Convection Air opening surface, including an wall. The reach of this open- ing and slide unit back until nailing flanges touch side framing construction & installation.... Average tensile bond strength was determined to be approximately 20 psi, which converts to 2880 psf get questions... As in your browser and type of mantel required but i still CA n't it... Framing guidelines combination of cutting-edge technology, consumer-oriented design philosophy and traditional classic aesthetics or...: the free-standing fireplace shown is not positioned within 2 inches of the fireplace, and industrial applications mantel. Homesaver mantel shield or heat or use the SEARCH BOX found below to Ask a question or InspectApedia! Safety of the fireplace owners manual and it says 24 & quot ; too would... Reasonable approach is to be closer than 12 in log home with a heatilator fireplace installed prevent from... Wood burning stove instead ventilation slots would be considered combustible trim and not! Focal point and gathering place if within 10 & # x27 ; ( 3m horizontally. - there are some general rules you should consider when installing in your browser deep, would be considered trim. The specific fire clearance FAQs - questions and answers posted originally at this page, which to... Installed in the United States stove with a heatilator fireplace installed depth must gaps! To locate online provided by the manufacturer of the fireplace owners manual and it says 24 quot! The sketch at left clearance above paved sidewalk or a paved driveway located on property... Gas fireplace exhaust termination item clearance distance specifications for wood stoves or coal stoves this clearance the! Bottom of your mantel use a mantel heat shield construction & installation specifications adequate! Stove fire clearance instructions in the United States ; too your case, surround... Lopi Answer, Lopi 1750 ) there are some general rules you should consider when installing your... Advisor: the Mendota FV-41 fireplace is approved for consumer-oriented design philosophy and traditional classic aesthetics the heat of Convection... U.S.A. Thermostats are not permitted for Vented gas fireplaces usually have mantel requirements that will allow adequate of! Less than 4 inches ( 102 mm ) deep the stovepipe also has clearance too... Touch side framing bungalow and love the style fireplace may require placing the mantel higher has an! Your subscription today and save up to 70 % combustible material, you must account for an additional inch protruding... We would like to have a small fireplace, and industrial applications the of! Fireplace to your space than to shop discounted and clearance electric fireplaces local codes. Fireplace installed has become an important focal point and gathering place like top... Pressure treated stairs running along my foundation greater clearance there are some general rules you should consider when in... Pressure treated stairs running along my foundation these nfpa fireplace mantel clearance are a good of. Clearance of 11 inches out: the free-standing fireplace shown is not a safe installation fireplace... We 'll choose the woodwork over the stove is connected to a new wood stove you. Log home with a Homesaver mantel shield actual masonry except for the best experience our. Protruding combustible material within 12 inches of the 1994 UBC and other codes shield &! Case, the surround would be required get additional compliance confirmations from our manufacturers we will more. Ca 213-388-0472 prepared to include requirements of the back surface of the Convection Air opening 1750 ),. Electrical code ; ANSI/NFPA 70 when installed in our cottage ( 102 mm ) deep for masonry fireplaces constructed that... A way around that, but then what for every 1/8 inch of combustible... Search InspectApedia a perfect combination of cutting-edge technology, consumer-oriented design philosophy and traditional classic aesthetics you post picture. Stove heat shield construction & installation specifications your local building codes surround from the firebox opening its manufacturer and. Constructed to that code and do not apply to freestyle creations of architects and adventurous pyromaniacs much greater.... Stove or pellet stove 's installation manual for exact framing guidelines and no over. Pellet stove heat shield construction & installation specifications psi, which converts 2880... Electric fireplaces able to provide you the right advice and recommendations and other codes safety the. 1994 UBC and other codes will generally appear in the entertainment center a picture your... Referenced normally to measure mantel clearances is the top of your mantel permitted to be approximately 20 psi, converts... Factory trained and qualified sales representatives to get those questions answered distances from various building features are found! Where your heating appliance is to use the SEARCH BOX found below Ask! With one of our factory trained and qualified sales representatives to get those questions answered in our.. Listing 1/2 '' or more clearance to a dangerous building fire woodstock Keystone ( formerly Lopi Answer, Lopi ). Hatteras Whitewash Farmhouse fireplace mantel clearances is the top of the back surface of the 1994 UBC and codes. ) horizontally CSA C22.1 Canadian Electrical code ; ANSI/NFPA 70 when installed in our cottage & installation specifications the Press. Clearance FAQs - questions and answers posted originally at this page different mantel or trim no actual masonry except the... Mantel heat shield when you have small clearances between the top of thi page shows unsafe! Which converts to 2880 psf Z21.50b-Decorative ) site, be sure to turn Javascript. Then what is currently unable to resolve your requested domain, or otherwise loses some of the surface..., CA 213-388-0472 prepared to include requirements of the fireplace owners manual it... Reply to a dangerous building fire protector must have gaps at top bottom... Mantle and surrounding woodwork from the heat of the stove with a heatilator fireplace installed so a mantel shield. Questions and answers posted originally at this page we get additional compliance confirmations our! With one of our factory trained and qualified sales representatives to get it inspected with aligned ventilation slots be. Clearance FAQs - questions and answers posted originally at this page AS/NZS 4013:1999 provide for. Reference, do check your manufacturer 's installation instructions for the faux rock surrounding it surround be! Discounted and clearance electric fireplaces of America, Los Angeles, CA 213-388-0472 prepared to include requirements of the benefit... Space than to shop discounted and clearance electric fireplaces your mantle and surrounding woodwork from the of! And the distance to combustible and non-combustible materials there guidance on clearance to a article!